Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
N Engl J Med ; 390(15): 1382-1393, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38587239

RESUMEN

BACKGROUND: The effects of temporary mechanical circulatory support with a microaxial flow pump on mortality among patients with ST-segment elevation myocardial infarction (STEMI) complicated by cardiogenic shock remains unclear. METHODS: In an international, multicenter, randomized trial, we assigned patients with STEMI and cardiogenic shock to receive a microaxial flow pump (Impella CP) plus standard care or standard care alone. The primary end point was death from any cause at 180 days. A composite safety end point was severe bleeding, limb ischemia, hemolysis, device failure, or worsening aortic regurgitation. RESULTS: A total of 360 patients underwent randomization, of whom 355 were included in the final analysis (179 in the microaxial-flow-pump group and 176 in the standard-care group). The median age of the patients was 67 years, and 79.2% were men. Death from any cause occurred in 82 of 179 patients (45.8%) in the microaxial-flow-pump group and in 103 of 176 patients (58.5%) in the standard-care group (hazard ratio, 0.74; 95% confidence interval [CI], 0.55 to 0.99; P = 0.04). A composite safety end-point event occurred in 43 patients (24.0%) in the microaxial-flow-pump group and in 11 (6.2%) in the standard-care group (relative risk, 4.74; 95% CI, 2.36 to 9.55). Renal-replacement therapy was administered to 75 patients (41.9%) in the microaxial-flow-pump group and to 47 patients (26.7%) in the standard-care group (relative risk, 1.98; 95% CI, 1.27 to 3.09). CONCLUSIONS: The routine use of a microaxial flow pump with standard care in the treatment of patients with STEMI-related cardiogenic shock led to a lower risk of death from any cause at 180 days than standard care alone. The incidence of a composite of adverse events was higher with the use of the microaxial flow pump. (Funded by the Danish Heart Foundation and Abiomed; DanGer Shock ClinicalTrials.gov number, NCT01633502.).


Asunto(s)
Corazón Auxiliar , Infarto del Miocardio con Elevación del ST , Choque Cardiogénico , Anciano , Femenino , Humanos , Masculino , Corazón Auxiliar/efectos adversos , Incidencia , Choque Cardiogénico/etiología , Choque Cardiogénico/mortalidad , Choque Cardiogénico/cirugía , Infarto del Miocardio con Elevación del ST/complicaciones , Infarto del Miocardio con Elevación del ST/mortalidad , Infarto del Miocardio con Elevación del ST/terapia , Resultado del Tratamiento , Circulación Asistida/efectos adversos , Circulación Asistida/instrumentación , Circulación Asistida/métodos
2.
Am J Cardiol ; 211: 299-306, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-37984636

RESUMEN

With increased use of transcatheter aortic valve implantation (TAVI) in treatment of aortic stenosis, it is important to evaluate real life data trends in outcomes. This nationwide register-based study aimed to present an outlook on temporal trends in characteristics and outcomes, including mortality. First-time consecutive Danish patients who underwent TAVI from 2010 to 2019 were included in this study. The chi-square and Kruskal-Wallis tests were performed to assess the differences in the characteristics over time and Cochrane-Armitage trend tests were used to examine changes in complications and mortality. Between 2010 and 2019, 4,847 patients (54.6% men, median age 82 [quartile 1 to quartile 3: 77 to 85] years) underwent first-time TAVI. A statistically significant decrease over time was observed for preprocedural hypertension, ischemic heart disease, and heart failure, whereas preexisting chronic obstructive lung disease and preprocedural pacemaker remained stable. We observed a significant decrease in 30- and 90-day postoperative preprocedural pacemaker implantation from 2011 to 2017, with 15.1% and 15.9% in 2011 and 8.6% and 8.9% in 2017, respectively. The incidence of for 30- and 90-day heart failure significantly decreased from 19.3% and 20.3% to 8.5% and 9.1%, respectively. We observed significant changes for 30-day atrial fibrillation, whereas the changes over time for 90-day atrial fibrillation and 30- and 90-day stroke/transient ischemic attack remained insignificant. The all-cause mortality within 30- and 90 days significantly decreased over time from 6.7% and 9.2% in 2011 to 1.5% and 2.7% in 2019 and 2016, respectively. In conclusion, this national study provides general insight on the trends of complications and mortality of TAVI, demonstrating significant reductions over time.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano de 80 o más Años , Femenino , Válvula Aórtica/cirugía , Fibrilación Atrial/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/cirugía , Estenosis de la Válvula Aórtica/cirugía , Insuficiencia Cardíaca/cirugía , Resultado del Tratamiento , Factores de Riesgo
3.
Front Cardiovasc Med ; 10: 1161779, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37529710

RESUMEN

Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries.

4.
EuroIntervention ; 19(8): 676-683, 2023 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-37584207

RESUMEN

BACKGROUND: Target lesion failure (TLF) remains an issue with contemporary drug-eluting stents. The dual-therapy sirolimus-eluting and CD34 antibody-coated COMBO stent (DTS) was designed to improve early healing. AIMS: We aimed to compare the 3-year outcomes of the DTS and the sirolimus-eluting Orsiro stent (SES) in all-comer patients treated with percutaneous coronary intervention. METHODS: The SORT OUT X trial is a prospective multicentre randomised clinical trial with a registry-based follow-up comparing DTS and SES. The primary endpoint, TLF, is a composite of cardiac death, myocardial infarction or target lesion revascularisation (TLR). RESULTS: A total of 3,146 patients were randomised to treatment with the DTS (1,578 patients) or the SES (1,568 patients). At 3 years, an intention-to-treat analysis showed that 155 patients (9.8%) who were assigned the DTS and 118 patients (7.5%) who were assigned the SES met the primary endpoint (incidence rate ratio for TLF=1.33, 95% confidence interval: 1.04-1.70; p=0.02). This difference was caused by a significantly higher TLF rate in the DTS group compared to the SES group within the first year, which was mainly explained by a higher incidence of TLR in the DTS group compared to the SES group. Of note, the TLF rates were almost identical from 1 year to 3 years in both stent groups. CONCLUSIONS: At 3 years, the SES was superior to the DTS, mainly because the DTS was associated with an increased risk of TLF within the first year but not from 1 to 3 years. CLINICALTRIALS: gov: NCT03216733.

5.
Catheter Cardiovasc Interv ; 101(4): 787-797, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36740229

RESUMEN

AIMS: Early healing after drug-eluting stent (DES) implantation may reduce the risk of stent thrombosis. The aim of this study was to compare patterns of early healing after implantation of the thin strut everolimus-eluting Synergy DES (Boston Scientific) or the biolimus-eluting Biomatix Neoflex DES (Biosensors). METHODS AND RESULTS: A total of 160 patients with the chronic or acute coronary syndrome were randomized 1:1 to Synergy or Biomatrix DES. Optical coherence tomography (OCT) was performed at baseline and at either 1- or 3-month follow-up. The primary endpoint was a coronary stent healing index (CSHI), a weighted index of strut coverage, neointimal hyperplasia, malapposition, and extrastent lumen. A total of 133 cases had OCT follow-up and 119 qualified for matched OCT analysis. The median CSHI score did neither differ significantly between the groups at 1 month: Synergy 8.0 (interquartile range [IQR]: 3.0; 14.0) versus Biomatrix 8.5 (IQR: 4.0; 15.0) (p = 0.47) nor at 3 months: Synergy 6.5 (IQR: 2.0; 13.0) versus Biomatrix 6.0 (IQR: 4.0; 11.0) (p = 0.83). Strut coverage was 84.6% (IQR: 72.0; 97.9) for Synergy versus 77.6% (IQR: 70.1; 90.3) for Biomatrix (p = 0.15) at 1 month and 90.3% (IQR 79.0; 98.8) (Synergy) versus 83.9% (IQR: 77.5; 92.6) (Biomatrix) (p = 0.068) at 3 months. Pooled 1- and 3-month coverage was 88.6% (IQR: 74.4; 98.4) for Synergy compared with 80.7% (IQR: 73.2; 90.8) for Biomatrix (p = 0.02). CONCLUSIONS: The early healing response after treatment with the Synergy or Biomatrix DES did not differ significantly as determined by a healing index. The Synergy DES showed overall better early stent strut coverage.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Everolimus , Enfermedad de la Arteria Coronaria/terapia , Polímeros , Implantes Absorbibles , Resultado del Tratamiento , Diseño de Prótesis , Tomografía de Coherencia Óptica
6.
Catheter Cardiovasc Interv ; 101(1): 13-21, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378691

RESUMEN

OBJECTIVES: To compare the efficacy and safety of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (O-SES) in patients with and without acute coronary syndrome (ACS) included in the SORT OUT X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with ACS when compared to patients without ACS. Whether the results from the SORT OUT X study apply to patients with and without ACS remains unknown. METHODS: In total, 3146 patients were randomized to stent implantation with DTS (n = 1578; ACS: n = 856) or O-SES (n = 1568; ACS: n = 854). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was higher in the DTS group compared to the O-SES group, both among patients with ACS (6.7% vs. 4.1%; incidence rate ratio: 1.65 [95% confidence interval, CI: 1.08-2.52]) and without ACS (6.0% vs. 3.2%; incidence rate ratio: 1.88 [95% CI: 1.13-3.14]). The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without ACS CONCLUSION: Compared to the O-SES, the DTS was associated with a higher risk of TLF at 12 months in patients with and without ACS. The differences were mainly explained by higher rates of TLR.


Asunto(s)
Síndrome Coronario Agudo , Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Sirolimus/efectos adversos , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/complicaciones , Enfermedad de la Arteria Coronaria/terapia , Factores de Riesgo , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Implantes Absorbibles , Fármacos Cardiovasculares/efectos adversos , Factores de Tiempo , Diseño de Prótesis , Infarto del Miocardio/etiología , Stents Liberadores de Fármacos/efectos adversos
7.
Eur Heart J Qual Care Clin Outcomes ; 9(5): 529-536, 2023 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-36195332

RESUMEN

AIMS: Standardized data definitions are necessary for the quantification of quality of care and patient outcomes in observational studies and randomised controlled trials (RCTs). The European Unified Registries for Heart Care Evaluation and Randomised Trials (EuroHeart) project of the European Society of Cardiology (ESC) aims to create pan-European data standards for cardiovascular diseases and interventions, including transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: We followed the EuroHeart methodology for cardiovascular data standard development. A Working Group of 29 members representing 12 countries was established and included a patient representative, as well as experts in the management of valvular heart disease from the European Association of Percutaneous Cardiovascular Interventions (EAPCI), the European Association of Cardiovascular Imaging (EACVI) and the Working Group on Cardiovascular Surgery. We conducted a systematic review of the literature and used a modified Delphi method to reach consensus on a final set of variables. For each variable, the Working Group provided a definition, permissible values, and categorized the variable as mandatory (Level 1) or additional (Level 2) based on its clinical importance and feasibility. In total, 93 Level 1 and 113 Level 2 variables were selected, with the level 1 variables providing the dataset for registration of patients undergoing TAVI on the EuroHeart IT platform. CONCLUSION: This document provides details of the EuroHeart data standards for TAVI processes of care and in-hospital outcomes. In the context of EuroHeart, this will facilitate quality improvement, observational research, registry-based RCTs and post-marketing surveillance of devices, and pharmacotherapies. ONE-SENTENCE SUMMARY: The EuroHeart data standards for transcatheter aortic valve implantation (TAVI) are a set of internationally agreed data variables and definitions that once implemented will facilitate improvement of quality of care and outcomes for patients receiving TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Sistema de Registros , Ensayos Clínicos Controlados Aleatorios como Asunto
8.
Front Cardiovasc Med ; 9: 1045280, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36505358

RESUMEN

Transcatheter aortic valve replacement (TAVR) is a recommended intervention for selected population with severe aortic stenosis (AS). Bicuspid aortic valve (BAV) anatomy has been categorized as an unfavorable anatomy for TAVR due to multiple considerations as exclusion from randomized trials in addition to the challenging and unpredictable anatomy. The anatomical constraints of BAV include the large anatomy of the annulus, sinus of Valsalva, and aorta (aortopathy), in addition to significant calcifications of the device landing zone. Most commercial transcatheter heart valves (THV) have upper dimension limits of the annulus and area in which the device can be implanted safely without significant oversizing. Myval-XL THVs (Meril Life Sciences Pvt. Ltd., India) are balloon-expandable valves (BEV) that have been developed with two new sizes, 30.5 and 32 mm, aiming to treat patients with large annulus dimensions and that exceed the upper limit of an ordinary device's sizing matrix. This case series report describes TAVR using the XL-Myval 32 mm THV in three European patients with symptomatic severe bicuspid aortic stenosis with significant calcifications and large annular dimensions exceeding the limits of the other THVs.

9.
Eur Heart J Acute Cardiovasc Care ; 11(10): 742-748, 2022 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-36006808

RESUMEN

AIMS: Stent implantation during primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI) occasionally results in flow disturbances and distal embolization, which may cause adverse clinical outcomes. Deferred stent implantation seems to reduce the impairment on myocardial function, although the mechanisms have not been clarified. We sought to evaluate whether deferred stenting could reduce flow disturbance in patients treated with primary PCI. METHODS AND RESULTS: Patients with STEMI included in the DANAMI-3-DEFER trial were randomized to deferred versus immediate stent implantation. The primary and secondary outcomes of this substudy were the incidences of slow/no reflow and distal embolization. A total of 1205 patients were included. Deferred stenting (n = 594) resulted in lower incidences of distal embolization [odds ratio (OR) 0.67, 95% confidence interval (CI) 0.46-0.98, P = 0.040] and slow/no reflow (OR 0.60, 95%CI 0.37-0.97, P = 0.039). In high-risk subgroups, the protective effect was greatest in patients >65 years of age (slow/no reflow: OR 0.36, 95% CI 0.17-0.72, P = 0.004 and distal embolization: OR 0.34, 95% CI 0.18-0.63, P = 0.001), in patients presenting with occluded culprit artery at admission (slow/no reflow: OR 0.33, 95% CI 0.16-0.65, P = 0.001 and distal embolization: OR 0.54, 95% CI 0.31-0.96, P = 0.036) and in patients with thrombus grade >3 (slow/no reflow: OR 0.37, 95% CI 0.20-0.67, P = 0.001 and distal embolization: OR 0.39, 95% CI 0.24-0.64, P < 0.001) with a significant P for interaction for all. CONCLUSION: Deferred stent implantation reduces the incidences of slow/no reflow and distal embolization, especially in older patients and in those with total coronary occlusion or high level of thrombus burden.


Asunto(s)
Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Anciano , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/cirugía , Infarto del Miocardio con Elevación del ST/etiología , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento , Stents , Miocardio , Angiografía Coronaria/métodos
10.
Catheter Cardiovasc Interv ; 99(7): 1965-1975, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35384254

RESUMEN

OBJECTIVES: To compare the efficacy and safety of the dual therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (SES) in patients with and without diabetes mellitus (DM) included in the Scandinavian Organization for Randomized Trials with Clinical Outcome (SORT OUT) X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with DM when compared to patients without DM. Thus, whether the results from the SORT OUT X study apply to patients with and without DM remains unknown. METHODS: In total 3146 patients were randomized to stent implantation with DTS (n = 1578; DM: n = 279) or SES (n = 1568; DM: n = 271). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was increased in the DTS group compared to the SES group, both among patients with DM (9.3% vs. 4.8%; risk difference: 4.5%; incidence rate ratio: 1.99, 95% confidence interval [CI]: 1.02-3.90) and without DM (5.7% vs. 3.5%; incidence rate ratio: 1.67, 95% CI: 1.15-2.42). The differences were mainly explained by higher rates of TLR. CONCLUSION: Compared to the SES, the DTS was associated with an increased risk of TLF at 12 months in patients with and without DM. The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without DM.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Infarto del Miocardio , Intervención Coronaria Percutánea , Implantes Absorbibles , Antígenos CD34/inmunología , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/terapia , Muerte , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Humanos , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Sirolimus/efectos adversos , Stents , Resultado del Tratamiento
11.
J Clin Med ; 11(2)2022 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-35054137

RESUMEN

Bicuspid aortic valve (BAV) is the most common valvular congenital anomaly and is apparent in nearly 50% of candidates for AV replacement. While transcatheter aortic valve implantation (TAVI) is a recommended treatment for patients with symptomatic severe aortic stenosis (AS) at all surgical risk levels, experience with TAVI in severe bicuspid AS is limited. TAVI in BAV is still a challenge due to its association with multiple and complex anatomical considerations. A retrospective study has been conducted to investigate TAVI's procedural and 30-day outcomes using the Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd. Vapi, Gujarat, India) in patients with severe bicuspid AS. Data were collected on 68 patients with severe bicuspid AS who underwent TAVI with the Myval THV. Baseline characteristics, procedural, 30-day echocardiographic and clinical outcomes were collected. The mean age and STS PROM score were 72.6 ± 9.4 and 3.54 ± 2.1. Procedures were performed via the transfemoral route in 98.5%. Major vascular complications (1.5%) and life-threatening bleeding (1.5%) occurred infrequently. No patient had coronary obstruction, second valve implantation or conversion to surgery. On 30-day echocardiography, the mean transvalvular gradient and effective orifice area were 9.8 ± 4.5 mmHg and 1.8 ± 0.4 cm2, respectively. None/trace aortic regurgitation occurred in 76.5%, mild AR in 20.5% and moderate AR in 3%. The permanent pacemaker implantation rate was 8.5% and 30-day all-cause death occurred in 3.0% of cases. TAVI with the Myval THV in selected BAV anatomy is associated with favorable short-term hemodynamic and clinical outcomes.

12.
Coron Artery Dis ; 33(3): 196-205, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-34985003

RESUMEN

OBJECTIVE: To evaluate the difference in early vascular healing between the ultrathin-strut biodegradable-polymer sirolimus-eluting Orsiro stent (O-SES) and the polymer-free biolimus-A9-eluting BioFreedom stent (BF-BES), assessed with optical coherence tomography (OCT) after primary percutaneous coronary intervention (PCI) in patients with ST-segment elevation myocardial infarctions (STEMIs). METHODS: Eighty patients with STEMI who underwent primary PCI were randomly allocated 1:1 to treatment with BF-BES or O-SES. OCT was acquired after PCI and at 1-month follow-up. The primary endpoint was 1-month OCT-assessed vascular healing index based on the presence of uncovered and malapposed stent struts and intraluminal filling defects where low vascular healing index indicated favorable vascular healing. RESULTS: At 1-month, the vascular healing index was similar in O-SES 11.5 [interquartile range (IQR) 9.5-17.5], compared to BF-BES 11.5 (IQR 7.1-12.5; P = 0.14). Percentage of uncovered struts [O-SES 31.5% (IQR 20.7-41.9), P = 0.43] vs. BF-BES 27.8% (IQR 19.4-41.9; P = 0.44), and median volume of neointimal hyperplasia [O-SES 4.9 mm3 (IQR 1.4-13.1) vs. BF-BES 7.1 mm3 (IQR 2.8-17.0), P = 0.18] did not differ significantly between the two stent groups. Complete coverage was not observed in any of the stents. The percentages of stents with malapposition did not differ significantly (O-SES 87.1% vs. BF-BES 71.4%, P = 0.14) whereas percentage of malapposed struts [O-SES 3.5% (IQR 0.8-5.5) vs. BF-BES 0.8% (IQR 0.0-1.8), P = 0.003] was lower in the BF-BES group. CONCLUSION: In patients with STEMI, the drug-coated BF-BES and the thin strut O-SES had similar vascular healing index at 1-month. However, the thin O-SES struts were more often malapposed.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Implantes Absorbibles , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Polímeros , Diseño de Prótesis , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/terapia , Sirolimus , Stents , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento
13.
Circulation ; 143(22): 2155-2165, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33823606

RESUMEN

BACKGROUND: Target lesion failure remains an issue with contemporary drug-eluting stents. Thus, the dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo stent (DTS) was designed to further improve early healing. This study aimed to investigate whether the DTS is noninferior to the sirolimus-eluting Orsiro stent (SES) in an all-comers patient population. METHODS: The SORT OUT X (Combo Stent Versus Orsiro Stent) trial, was a large-scale, randomized, multicenter, single-blind, 2-arm, noninferiority trial with registry-based follow-up. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction, or target lesion revascularization within 12 months, analyzed using intention-to-treat. The trial was powered for assessing target lesion failure noninferiority of the DTS compared with the SES with a predetermined noninferiority margin of 0.021. RESULTS: A total of 3146 patients were randomized to treatment with the DTS (1578 patients; 2008 lesions) or SES (1568 patients; 1982 lesions). At 12 months, intention-to-treat analysis showed that 100 patients (6.3%) assigned the DTS and 58 patients (3.7%) assigned the SES met the primary end point (absolute risk difference, 2.6% [upper limit of 1-sided 95% CI, 4.1%]; P (noninferiority)=0.76). The SES was superior to the DTS (incidence rate ratios for target lesion failure, 1.74 [95% CI, 1.26-2.41]; P=0.00086). The difference was explained mainly by a higher incidence of target lesion revascularization in the DTS group compared with the SES group (53 [3.4%] vs. 24 [1.5%]; incidence rate ratio, 2.22 [95% CI, 1.37-3.61]; P=0.0012). CONCLUSIONS: The DTS did not confirm noninferiority to the SES for target lesion failure at 12 months in an all-comer population. The SES was superior to the DTS mainly because the DTS was associated with an increased risk of target lesion revascularization. However, rates of death, cardiac death, and myocardial infarction at 12 months did not differ significantly between the 2 stent groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03216733.


Asunto(s)
Antibacterianos/uso terapéutico , Antígenos CD34/metabolismo , Stents Liberadores de Fármacos/normas , Intervención Coronaria Percutánea/métodos , Sirolimus/uso terapéutico , Anciano , Antibacterianos/farmacología , Femenino , Humanos , Masculino , Sirolimus/farmacología , Resultado del Tratamiento
14.
Acta Anaesthesiol Scand ; 65(7): 936-943, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33728635

RESUMEN

BACKGROUND: Veno-arterial extracorporeal membrane oxygenation (V-A ECMO) is commonly used to provide haemodynamic support for patients with severe cardiac failure. However, timing ECMO weaning remains challenging. We aimed to examine if an integrative weaning approach based on predefined haemodynamic, respiratory and echocardiographic criteria is associated with successful weaning. METHODS: All patients weaned from ECMO between April 2017 and April 2019 at Aarhus University Hospital, Denmark, were consecutively enrolled. Predefined haemodynamic, respiratory and echocardiographic criteria were assessed before and during ECMO flow reduction. A weaning attempt was commenced in haemodynamic stable patients and patients remaining stable at minimal flow were weaned from ECMO. Comparisons were made between patients who met the criteria for weaning at first attempt and patients who did not meet these criteria. Patients completing a full weaning attempt with no further need for mechanical support within 24 h were defined as successfully weaned. RESULTS: A total of 38 patients were included in the study, of whom 26 (68%) patients met the criteria for weaning. Among these patients, 25 (96%) could be successfully weaned. Successfully weaned patients were younger and had less need for inotropic support and ECMO duration was shorter. Fulfilling the weaning criteria was associated with successful weaning and both favourable 30-d survival and survival to discharge. CONCLUSION: An integrative weaning approach based on haemodynamic, respiratory and echocardiographic criteria may strengthen the clinical decision process in predicting successful weaning in patients receiving ECMO for refractory cardiac failure.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Ecocardiografía , Insuficiencia Cardíaca/terapia , Hemodinámica , Humanos , Estudios Retrospectivos
15.
Catheter Cardiovasc Interv ; 97(6): 1270-1278, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33347739

RESUMEN

OBJECTIVES: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. BACKGROUND: The MANTA is a novel plug-based device for large bore arteriotomy closure. METHODS: We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. RESULTS: Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 ± 6.6 years with a median STS-score of 2.7 [IQR 2.0-4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20-120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. CONCLUSION: In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions.


Asunto(s)
Aneurisma de la Aorta Abdominal , Estenosis de la Válvula Aórtica , Implantación de Prótesis Vascular , Cateterismo Periférico , Procedimientos Endovasculares , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Periférico/efectos adversos , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Hemorragia/etiología , Técnicas Hemostáticas/efectos adversos , Humanos , Sistema de Registros , Resultado del Tratamiento
16.
J Am Heart Assoc ; 9(5): e015133, 2020 03 03.
Artículo en Inglés | MEDLINE | ID: mdl-32102615

RESUMEN

Background As younger patients are being considered for transcatheter aortic valve implantation (TAVI), the assessment and treatment of concomitant coronary artery disease is taking on increased importance. Methods and Results Thirteen contemporary lower-risk patients with TAVI with severe aortic stenosis (AS) and moderate-severe coronary lesions were included. Patients underwent assessment of coronary hemodynamics in the presence of severe AS (pre-TAVI), in the absence of severe AS (immediately post-TAVI), and at longer-term follow-up (6 months post-TAVI). Fractional flow reserve decreased from 0.85 (0.76-0.88) pre-TAVI to 0.79 (0.74-0.83) post-TAVI, and then to 0.71 (0.65-0.77) at 6-month follow-up (P<0.001 for all comparisons). Conversely, instantaneous wave-free ratio was not significantly different: 0.82 (0.80-0.90) pre-TAVI, 0.83 (0.77-0.88) post-TAVI, and 0.83 (0.73-0.89) at 6 months (P=0.735). These changes are explained by the underlying coronary flow. Hyperemic whole-cycle coronary flow (fractional flow reserve flow) increased from 26.36 cm/s (23.82-31.82 cm/s) pre-TAVI to 30.78 cm/s (29.70-34.68 cm/s) post-TAVI (P=0.012), to 40.20 cm/s (32.14-50.00 cm/s) at 6-month follow-up (P<0.001 for both comparisons). Resting flow during the wave-free period of diastole was not significantly different: 25.48 cm/s (21.12-33.65 cm/s) pre-TAVI, 24.54 cm/s (20.74-27.88 cm/s) post-TAVI, and 25.89 cm/s (22.57-28.96 cm/s) at 6 months (P=0.500). Conclusions TAVI acutely improves whole-cycle hyperemic coronary flow, with ongoing sustained improvements at longer-term follow-up. This enhanced response to hyperemic stimuli appears to make fractional flow reserve assessment less suitable for patients with severe AS. Conversely, resting diastolic flow is not significantly influenced by the presence of severe AS. Resting indices of coronary stenosis severity, therefore, appear to be more appropriate for this patient population, although large-scale prospective randomized trials will be required to determine the role of coronary physiology in patients with severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Enfermedad de la Arteria Coronaria/complicaciones , Circulación Coronaria/fisiología , Estenosis Coronaria/complicaciones , Femenino , Estudios de Seguimiento , Reserva del Flujo Fraccional Miocárdico/fisiología , Humanos , Masculino , Factores de Tiempo , Resultado del Tratamiento , Resistencia Vascular/fisiología
17.
N Engl J Med ; 382(2): 130-139, 2020 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-31733182

RESUMEN

BACKGROUND: Subclinical leaflet thickening and reduced leaflet motion of bioprosthetic aortic valves have been documented by four-dimensional computed tomography (CT). Whether anticoagulation can reduce these phenomena after transcatheter aortic-valve replacement (TAVR) is not known. METHODS: In a substudy of a large randomized trial, we randomly assigned patients who had undergone successful TAVR and who did not have an indication for long-term anticoagulation to a rivaroxaban-based antithrombotic strategy (rivaroxaban [10 mg] plus aspirin [75 to 100 mg] once daily) or an antiplatelet-based strategy (clopidogrel [75 mg] plus aspirin [75 to 100 mg] once daily). Patients underwent evaluation by four-dimensional CT at a mean (±SD) of 90±15 days after randomization. The primary end point was the percentage of patients with at least one prosthetic valve leaflet with grade 3 or higher motion reduction (i.e., involving >50% of the leaflet). Leaflet thickening was also assessed. RESULTS: A total of 231 patients were enrolled. At least one prosthetic valve leaflet with grade 3 or higher motion reduction was found in 2 of 97 patients (2.1%) who had scans that could be evaluated in the rivaroxaban group, as compared with 11 of 101 (10.9%) in the antiplatelet group (difference, -8.8 percentage points; 95% confidence interval [CI], -16.5 to -1.9; P = 0.01). Thickening of at least one leaflet was observed in 12 of 97 patients (12.4%) in the rivaroxaban group and in 33 of 102 (32.4%) in the antiplatelet group (difference, -20.0 percentage points; 95% CI, -30.9 to -8.5). In the main trial, the risk of death or thromboembolic events and the risk of life-threatening, disabling, or major bleeding were higher with rivaroxaban (hazard ratios of 1.35 and 1.50, respectively). CONCLUSIONS: In a substudy of a trial involving patients without an indication for long-term anticoagulation who had undergone successful TAVR, a rivaroxaban-based antithrombotic strategy was more effective than an antiplatelet-based strategy in preventing subclinical leaflet-motion abnormalities. However, in the main trial, the rivaroxaban-based strategy was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than the antiplatelet-based strategy. (Funded by Bayer; GALILEO-4D ClinicalTrials.gov number, NCT02833948.).


Asunto(s)
Válvula Aórtica/fisiopatología , Aspirina/farmacología , Clopidogrel/farmacología , Inhibidores del Factor Xa/farmacología , Prótesis Valvulares Cardíacas , Inhibidores de Agregación Plaquetaria/farmacología , Rivaroxabán/farmacología , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/efectos de los fármacos , Válvula Aórtica/patología , Aspirina/efectos adversos , Aspirina/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Enfermedades Cardiovasculares/mortalidad , Clopidogrel/efectos adversos , Clopidogrel/uso terapéutico , Quimioterapia Combinada , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Femenino , Tomografía Computarizada Cuatridimensional , Hemorragia/inducido químicamente , Humanos , Análisis de Intención de Tratar , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Rivaroxabán/efectos adversos , Rivaroxabán/uso terapéutico , Tromboembolia/etiología , Tromboembolia/mortalidad
18.
Am J Cardiol ; 124(6): 825-832, 2019 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-31324357

RESUMEN

The optimal timing of coronary angiography (CAG) in high-risk patients with acute coronary syndrome without persisting ST-segment elevation (NST-ACS) remains undetermined. The NON-ST-Elevation Myocardial Infarction trial aimed to compare outcomes in NSTE-ACS patients randomized to acute CAG (STEMI-like approach) with patients randomized to medical therapy and subacute CAG. We randomized 496 patients with suspected NST-ACS based on symptoms and significant regional ST depressions and/or elevated point-of-care troponin T (POC-cTnT) (≥50 ng/l) to either acute CAG (<2 hours, n = 245) or subacute CAG (<72 hours, n = 251). The primary end point was a composite of all-cause death, reinfarction, and readmission with congestive heart failure within 1 year from randomization. A final acute coronary syndrome (ACS) diagnosis was assigned to 429 (86.5%) patients. The median time from randomization to revascularization was 1.3 hours in the acute CAG group versus 51.1 hours in the subacute CAG group (p <0.001). The composite end point occurred in 25 patients (10.2%) in the acute CAG group and 29 (11.6%) in the subacute CAG group, p = 0.62. The acute CAG group had a 1-year all-cause mortality of 5.7% compared with 5.6% in the subacute CAG group, p = 0.96. In conclusion, neither the composite end point of all-cause death, reinfarction, and readmission with congestive heart failure nor mortality differed between an acute and subacute CAG approach in NSTE-ACS patients. However, identification of NSTE-ACS patients in the prehospital phase and direct triage to an invasive center is feasible, safe and may facilitate early diagnosis and revascularization.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Electrocardiografía , Infarto del Miocardio sin Elevación del ST/diagnóstico , Anciano , Dinamarca/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio sin Elevación del ST/mortalidad , Tasa de Supervivencia/tendencias , Factores de Tiempo , Troponina T
19.
Am J Cardiol ; 124(5): 671-677, 2019 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31279405

RESUMEN

Diabetes mellitus is associated with a higher risk of target lesion revascularization after percutaneous coronary intervention. We compared clinical outcomes in patients with and without diabetes mellitus, treated with everolimus-eluting stents (EES; Synergy; Boston Scientific, Marlborough, Massachusetts) or biolimus-eluting stents (BES; BioMatrix NeoFlex; Biosensors Interventional Technologies Pte Ltd., Singapore). In total, 2,764 patients were randomized to stent implantation with EES (n = 1,385, diabetes: n = 250) or the BES (n = 1,379, diabetes: n = 262), stratified by gender and diabetes. The primary end point, target lesion failure (TLF), was a composite of cardiac death, target-lesion myocardial infarction, or target lesion revascularization at 12 months. Secondary end points included individual components of TLF, all-cause death, and stent thrombosis. TLF was 2.1% lower in the EES versus the BES groups in patients with diabetes (3.6% vs 5.7%; rate ratios 0.61, 95% confidence interval [CI] 0.27 to 1.41) and similar in patients without diabetes (4.1% vs 4.0%; rate ratios 0.99, 95% CI 0.66 to 1.51). In patients with diabetes, the point estimates of the individual components of TLF also favored the EES but CIs were wide. No interaction between stent type and presence of diabetes was found. The current subgroup analysis found that a thin-strut EES as compared with a thicker strut BES had a numerically lower TLF rate in patients with diabetes, but the subgroup analysis was underpowered for definite conclusions.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus/diagnóstico , Stents Liberadores de Fármacos/efectos adversos , Sirolimus/análogos & derivados , Sirolimus/administración & dosificación , Implantes Absorbibles , Anciano , Angioplastia Coronaria con Balón/mortalidad , Intervalos de Confianza , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Diabetes Mellitus/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Intervención Coronaria Percutánea/métodos , Valores de Referencia , Medición de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia , Resultado del Tratamiento
20.
Eur Heart J Acute Cardiovasc Care ; 8(4): 299-308, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29199427

RESUMEN

OBJECTIVE: The purpose of this study was to determine the predictive value of routine prehospital point-of-care cardiac troponin T measurement for diagnosis and risk stratification of patients with suspected acute myocardial infarction. METHODS AND RESULTS: All prehospital emergency medical service vehicles in the Central Denmark Region were equipped with a point-of-care cardiac troponin T device (Roche Cobas h232) for routine use in all patients with a suspected acute myocardial infarction. During the study period, 1 June 2012-30 November 2015, prehospital point-of-care cardiac troponin T measurements were performed in a total of 19,615 cases seen by the emergency medical service and 18,712 point-of-care cardiac troponin T measurements in 15,781 individuals were matched with an admission. A final diagnosis of acute myocardial infarction was confirmed in 2187 cases and a total of 2150 point-of-care cardiac troponin T measurements (11.0%) had a value ≥50 ng/l, including 966 with acute myocardial infarction (sensitivity: 44.2%, specificity: 92.8%). Patients presenting with a prehospital point-of-care cardiac troponin T value ≥50 ng/l had a one-year mortality of 24% compared with 4.8% in those with values <50 ng/l, log-rank: p<0.001. The following variables showed the strongest association with mortality in multivariable analysis: point-of-care cardiac troponin T≥50 ng/l (hazard ratio 2.10, 95% confidence interval: 1.90-2.33), congestive heart failure (hazard ratio 1.93, 95% confidence interval: 1.74-2.14), diabetes mellitus (hazard ratio 1.42, 95% confidence interval: 1.27-1.59) and age, one-year increase (hazard ratio 1.08, 95% confidence interval: 1.08-1.09). CONCLUSIONS: Patients with suspected acute myocardial infarction and a prehospital point-of-care cardiac troponin T ≥50 ng/l have a poor prognosis irrespective of the final diagnosis. Routine troponin measurement in the prehospital setting has a high predictive value and can be used to identify high-risk patients even before hospital arrival so that they may be re-routed directly for advanced care at an invasive centre.


Asunto(s)
Servicios Médicos de Urgencia/métodos , Infarto del Miocardio/diagnóstico , Sistemas de Atención de Punto , Medición de Riesgo , Troponina T/sangre , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Dinamarca/epidemiología , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/epidemiología , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...